Features
◎7"high resolution color TFT display
◎Rolling and refreshing waveform display;
◎Standard 5 parameters: ECG, RESP,NIBP, SPO2, 1-TEMP
◎Multi-display:standard,large font,trend coexis, OxyCRG dynamic
◎Up to 4 hours working capacity of built-in rechargeable battery.
◎5 Sepatated PCB board:main board, power,ECG, NIBP, SpO2
◎Optional:
◎Masimo/Nellcor Sp02, Suntech NIBP from USA, EtCO2, C.O., BIS
Configure
MINO7V-1: ECG+NIBP+SpO2+TEMP+RESP
MINO7V-2: ECG+SpO2
MINO7V-3: ECG+NIBP

MINO7V-4: SpO2+NIBP
MINO7V-5: NIBP
MINO7V-6: SpO2
MINO7V-7: EtCO2+SpO2
MINO7V-8: EtCO2+2IBP
MINO7V-9: EtCO2
Standard parameter
ECG:
Lead mode:5 –lead(R,L,F,N,C)
Lead selection :I,II,III,avR,avL,avF,V
Waveform: 3 and 7 channel selectable
Gain selection: 0.5mm/mv,1mm/mv,2mm/mv
Sweep speed: 12.5mm/s;25mm/s;50mm/s
Heart rate range: Adult: 15~300bpm;
Neonate/pediatric:15~350bpm
Accuracy: +1bpm or +1%,whichever is greater
Resolution: 1bpm
Filter:surgery mode:1~20Hz
monitor model:0.5~40Hz
Diagnostic mode:0.05~130Hz
Scaling signal: 1mv,+3%
Protection: withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation
Alarm range:15~350bpm
S-T segment detection:
Measurement range: 2.0mV~+2.0mV
Alarm Range: -2.0mV~ +2.0mV
Accuracy: -0.8mV ~+0.8Mv
Error: +0.02Mv
Arrhythmia analysis:YES
SPO2
Measurement range: 0~100%
Resolution: 1%
Accuracy: +2%(70-100%);0-69% unspecified
Alarm range 0~100%
Pulse Rate:
range: 20~300bpm
Resolution: 1bpm
Error: +1bpm or +2%,whichever is greater
NIBP
Method: Digital Automatic oscillometric
Operation mode : Manual/ Automatic/continuous
Auto measurement time: Adjustable(1~480min)
Measurement Unit: mmHg/Kpa selectable
Measurement types:Systolic, Diastolic, Mean
Measurement range:
Range of Systolic pressure: Adult: 40~270mmHg
Pediatric: 40~220mmHg
Neonate: 40~135mmHg
Range of mean pressure: Adult: 20~235mmHg
Pediatric: 20~165mmHg
Neonate: 20~110mmHg
Range of diastolic pressure: Adult: 10~215mmHg
Pediatric: 10~150mmHg
Neonate :10~100mmHg
Over-pressure protection: Double safety protection
Resolution: 1 mmHg
Alarm: Systolic.Diastolic,Mean
RESPIRATION
Method: Thoracic impedance
Measurement range: Adult:7~120rpm;
Neonate/Pediatric:7~150rpm
Apnea alarm: YES,10~40s
Resolution: 1rpm
Accuracy: +2rpm
TEMPERATURE
Compatible probe: YSI or CYF
Measurement range: 5~50℃
Resolution : 0.1℃
Accuracy: +0.1℃
Refreshing time: about 1
Average measuring time: <10s
IBP
Channel: 2 channels
Range: -50-300mmHg
Resolution: 1mmHg
Accuracy: ±4mmHg(±4%)
Unit: mmHg, Kpa
Converter Sensitivity: 5mV/V/mmHg
Transducer sites: ART/PA/CVP/LAP/RAP/ICP
EtCO2
Measurement range: 0~99mmHg
Accuracy: +2mmHg (0~40mmHg)
Sampling Range: 100ml/min
Sampling rate accuracy: 15%
Respiration rate: 0~120rmp
Respiration accuracy: +2rmp (0~70rmp)
+5rmp (>70rmp)
Respiration time: <240msec (10% to 90%)
Delay time: <2s
EtCO2 (mainstream CO2)
Method: Infrared Spectrum
Range: 0.0-10% (0~76%)
Resolution: 1mmHg (0.1%)
Accuracy: <5%(±4.0 mmHg)
Or<10%(of Readings)
Recorder: Build-in, thermal array
Plethysmogram waveform:2 channels
Record mode: manual, on alarm, time-defined
Recording width: 50mm
Printing speed: 50mm/s
Recording type: Frozen waveform record
Hot Tags: vital sign patient monitor, China, manufacturers, suppliers, factory, customized, wholesale, price, buy, for sale, in stock