+86 130 1292 1264
Electrosurgical Generator Instrument
video
Electrosurgical Generator Instrument

Electrosurgical Generator Instrument

Bipolar and Monopolar Electrosurgical Procedures for Medical Veterinary Practice---ESU-G5V, made by YUDA Medical, since 1992. ESUs are used in more than 80 percent of all surgical procedures, including veterinary. Electrosurgical unit procedures upgrade the decrease time of anesthesia . In addition, less time is required for post-surgical healing.
Send Inquiry
Product Details ofElectrosurgical Generator Instrument

Today, YUDAmade ESUs Model: G5V for veterinary has been virtually upgrade for a number of veterinary procedures, including:dermal lesions treatment, ear cropping, emergency care, eyelid surgery, spay/neutering, etc.

ESU -G5V has both bipolar and monopolar options with a high-frequency electrical current for cutting, coagulating, desiccating and fulgurating tissue advantages.

Design safety classification including: CF type, both monopolar and bipolar function, with pure cutting, mixed cutting I, mixed cutting II, soft blood coagulation, strong blood coagulation, double blood coagulation I, double blood coagulation II.

veterinary animal banner

Considering the high impedance of animal body, the output of hardware circuit is designed to match up the characteristics of animal body, this innovative electrosurgical unit ESU-G5V is particularly designed and improved.

The positive aspects are its power output, which is equipped with startup self-test, plate impedance monitoring, output short-circuit protection, power overcurrent protection, output feedback detection, power tube status monitoring, abnormal trigger protection and other measures, closed-loop working characteristics.

VET ESU-G5V 3
Model: ESU-G5V

Technical data:

Rated power: 300W, frequency:512KHz, impedance: 500 Ώ, 100Ώ.

Power redundancy design: the rated output power 300W, the power supply 400W for output power.

The description of monopolar electric subtangent mode:

Pure cut: Unmodulated continuous sine wave, simply performs a clean and precise cut of the tissue.

Mixed cut I: Modulated sine waves for a clean and precise cut of tissue ( common mode)

Mixed cut II: Modulated sine waves for a clean and precise cut of tissue ( The degree of condensation increases)

The description of monopolar subtangent mode:

Soft blood coagulation: modulated sine wave for soft coagulation of tissue (common mode).

Strong blood coagulation: modulated sinusoidal waves for strong coagulation of tissue.

The description of Bipolar coagulation mode

Double blood coagulation I: Soft coagulation act on blood vessels and small impedance tissue, by using continuous sine wave, it is a common mode.

Double blood coagulation II: Perform strengthened blood coagulation by modulated sine wave, act on small impedance tissue.